Sampling cooler
The company's products cover petrochemical, oil refining, and offshore oil companies affiliated to Sinopec Group Corporation, China National Petroleum Corporation, and China National Offshore Oil Corporation. It has a large number of customers in steel, food, medicine, environmental protection, electric power, coal chemical and other industries.
category:
Sampling cooler
1. Product Characteristics
Sampling cooler is suitable for sampling liquid and gas with high temperature. It has the advantages of compact structure, high heat transfer efficiency, easy cleaning and long service life. It is widely used in small heating and heat transfer of petroleum, chemical, light industry and electric power. Cooler can also be used as self-sealing cooler of oil pump.
2. Product Model
Single Phase Sampling Cooler (SCY-IA) as shown in Fig. 1, Table 1
Technical Characteristic Table | |||
Design pressure | Design temperature | Operating medium | Heat transfer area |
Tube range 3.92MPa | 350℃ | 0.08m2 | |
Shell side atmospheric pressure | 60℃ | water |
Specification type
(Drawing No.)
|
Operating medium | Coil material | Device opening DN | ||||
1 | 2 | 3 | 4 | 5 | |||
SCY-1A-1S5-10-1) | Oil products | 20 | 15 | 15 | 20 | 25 | G1/2 |
SCY-1A-2(S5-10-2) | Sulfur containing oil | 1Cr18Ni9Ti | 15 | 15 | 20 | 25 | G1/2 |
SCY-1A-3(S5-10-3) | Associated gas | 20 | 15 | 8(external diameter) | 20 | 25 | G1/2 |
SCY-1A-4(S5-10-4) | Sulfur-bearing hydrocarbon and hydrogen | 1Cr18Ni9Ti | 15 | 8(external diameter) | 20 | 25 | G1/2 |
Note: SCY-I A-3, 4 type openings (2) with_8 shrinkage.
Double Sampling Cooler (SCX-IB) see Figure 2
Technical Characteristic Table | ||||
Design pressure | Design temperature | Operating medium | Heat transfer area | |
Tube range | 0.58MPa | 172℃ | Steam and water | 1.04m2 |
Shell side | 0.58MPa | 60℃ | water |
Nozzle table | |||||
Orifice
number
|
Name or purpose | Number |
Nominal diameter DN(mm) |
Nominal pressure PN(Mpa) |
Remarks |
11-2 | Steam inlet | 2 | 10 | ||
21-2 | Steam outlet | 2 | 10 | ||
3 | Cooling water inlet | 1 | 40 | 2.0 | GB9115.12-88 |
4 | Cooling water outlet | 1 | 40 | 2.0 | GB9115.12-88 |
5 | Outfall | 1 | 50 | ||
61-2 | Upper row gap | 2 | G1/2 | Tube plug | |
71-2 | Downstream vent | 2 | G1/2 | Tube plug |
Quadruple Sampling Cooler (SCY-IC) as shown in Figure 3
Technical Characteristic Table | ||||
Design pressure | Design temperature | Operating medium | Heat transfer area | |
Tube range | 4.62MPa | 275℃ | Steam and water | 2.08m2 |
Shell side | 0.58MPa | 60℃ | water |
Nozzle table | |||||
Orifice
number
|
Name or purpose | Number |
Nominal diameter DN(mm) |
Nominal pressure PN(Mpa) |
Remarks |
11-4 | Steam inlet | 4 | 10 | ||
21-4 | Steam outlet | 4 | 10 | ||
3 | Cooling water inlet | 1 | 50 | 2.0 | GB9115.12-88 |
4 | Cooling water outlet | 1 | 50 | 2.0 | GB9115.12-88 |
5 | Outfall | 2 | 50 | ||
61-4 | Upper row gap | 4 | G1/2 | Tube plug | |
71-4 | Downstream vent | 4 | G1/2 | Tube plug |